Product description
Functions
This machine is meant for leak testing and acid filling/leveling.
Machine operation
After the operator has placed it on the conveyor, the battery is automatically sent to the first (1-3-5) air leak test station; if the battery fails, it is automatically rejected; if it is approved, it continues to the second test station (2-4-6), and is rejected or approved following the same procedure. Approved batteries are sent to the third (acid filling or extraction), fourth (acid extraction for level adjustment) and fifth station (final filling). The fifth and final station is equipped with an EIS system for checking the electrolyte level.
Product specification
|
Product specification |
Power consumption |
5 KW |
Dimensions |
approx. 3780 (W) × 2916 (D) × 2487 (H) mm |
Weight |
approx. 4000 kg |
More similar equipment on our
acid filling and
finishing line product pages.